Miele DA 259-4 EXT Petunjuk Pengoperasian dan Pemasangan - Halaman 30
Jelajahi secara online atau unduh pdf Petunjuk Pengoperasian dan Pemasangan untuk Kap Ventilasi Miele DA 259-4 EXT. Miele DA 259-4 EXT 36 halaman. Cooker
If the exhaust ducting is to run through
rooms, ceiling space etc. where there
may be great variations in temperature
between the different areas, the
problem of condensation will need to
be addressed. The exhaust ducting will
need to be suitably insulated.
(optional accessory)
In addition to insulating the exhaust
ducting, we recommend that a suitable
condensate trap is installed to collect
and evaporate any condensate which
may occur. Condensate traps are
available for C 125 mm or C 150 mm
ducting.
When installing a condensate trap,
ensure that it is positioned vertically
and if possible directly above the
exhaust connection. The arrow on the
housing indicates the direction of
air-flow.
30
To achieve even further reductions in
noise levels, a special silencer can be
fitted in the ducting system.
It can be sited at any suitable position
in the ducting system between the
cooker hood and the external motor on
EXT model cooker hoods.
On extraction models, it can be fitted
nearest the ducting outlet to the outside
to reduce neighbourhood noise.
On recirculation models, it can be fitted
in between the fan and the deflector.