Electrical connection
Important UK
If the appliance is fitted with a non-re-
wireable plug (BS 1363 UK) and the
socket outlets are not suitable for the
plug supplied, or if the existing plug
needs to be replaced by a new one,
the old plug will need to be cut off and
an appropriate plug fitted. The fuse car-
rier and the fuse should be removed
from the old plug and disposed of. The
plug cut from the cable should then be
disposed of, and on no account be in-
serted into any socket elsewhere in the
house (electric shock hazard).
The fuse cover must be re-fitted when
changing the fuse and if the fuse cover
is lost the plug must not be used until a
suitable replacement is obtained.
The colour of the correct replacement
cover is that of the coloured insert in
the base of the plug or the colour that
is embossed in words in the base of
the plug (as applicable to the design of
plug fitted).
The correct fuse rating of the replace-
ment fuses that are ASTA approved to
BS 1362 should be fitted. Replacement
fuse covers may be purchased from
your local electrical suppliers or Ser-
vice agent.
20
Important
The wires in the mains lead are col-
oured in accordance with the following
code:
Green/yellow = earth
Blue
= neutral
Brown
= live
If the appliance is to be connected via
a plug and socket, please note the fol-
lowing:
As the colours of the wires in the mains
lead of this appliance may not corre-
spond with the coloured markings
identifying the terminals in your plug,
proceed as follows:
The wire which is coloured green
and yellow must be connected to the
terminal in the plug which is marked
with the letter E or by the earth sym-
bol z or coloured green or green
and yellow.
The wire which is coloured blue must
be connected to the terminal which
is marked with the letter N or col-
oured black.
The wire which is coloured brown
must be connected to the terminal
which is marked with the letter L or
coloured red.
For Australia / New Zealand: The wire
which is coloured brown must be con-
nected to the terminal which is marked
with the letter A or coloured red.
WARNING:
THIS APPLIANCE MUST BE
EARTHED