When connecting the hood to an ex-
ternal vent, make sure that there is
adequate ventilation in the room
where the exhaust hood is to be
used.
When using the hood in the same area
as other appliances requiring room air
(e.g. non-electric water heaters, gas
cooktops, gas ovens, etc.) make cer-
tain that the air extracted by the hood
does not hinder their operation. These
appliances need air for combustion.
Adequate ventilation can be main-
tained by installing air vents in windows
or walls or by ensuring that the hood
can only be turned on when the other
appliances are off, or vice versa.
To prevent combustion gases being
drawn back into the room by the ex-
haust hood, the underpressure in the
room must be no greater than 0.0006 psi
(0.04 mbar) when the hood and these
appliances are running simultaneously.
If there are any doubts as to whether
there is adequate ventilation, consult
an experienced professional.