Vent ducting
^ If the on-site ventilation system does
not have a non-return flap, then the
non-return flap supplied with the
appliance must be fitted in the
exhaust socket in the motor unit.
^ When using C 150 mm ducting,
secure the exhaust connection
supplied to exhaust ducting with
hose clips.
^ If using C 125 mm ducting, fit the
reducing collar into the exhaust
connection, and secure the exhaust
ducting to the reducing collar with a
hose clip. (See "Connection for air
extraction").
^ Place the exhaust ducting on the fan
connection for the cooker hood.
^ See "Connection for air extraction" for
further instructions on fitting the
ducting.
Installation