Safety distance between hob and
cooker hood (S)
For safety reasons a minimum safety
distance must be maintained
between the top of the cooker/hob
and the bottom of the cooker hood:
- 550 mm above electric cookers/hobs
- 650 mm above an open grill from
the Miele range.
- 650 mm above gas cookers/hobs
If this cooker hood is installed above
a Miele Wok CS 1028 CombiSet
appliance, a minimum safety
distance of 760 mm must be
maintained between the burner and
the lower edge of the cooker hood.
See the Warning and Safety
instructions for further information.
A distance of 650 mm above the hob
may be preferable to give more working
space.