Miele DA 416-4 Panduan Pengoperasian dan Instalasi - Halaman 21

Jelajahi secara online atau unduh pdf Panduan Pengoperasian dan Instalasi untuk Kap Ventilasi Miele DA 416-4. Miele DA 416-4 36 halaman. Cooker

Miele DA 416-4 Panduan Pengoperasian dan Instalasi
Extraction
Recirculation
Ventilation grille positioned at the top
for recirculation
,
(
is not required for recirculation
mode cooker hoods).The shaded areas
represent the wall or ceiling area for the
vent cut-out and for fitting the
connection socket.
For recirculation mode, only a
connection socket needs to be fitted.
Connection for air extraction
C 150 mm, or C 125 mm with reducing
collar.
Appliance dimensions
Safety distance between hob and
cooker hood (S)
When planning the installation height
of your cooker hood, the minimum
safety distances between the top of
a cooker or hob and the bottom of
the cooker hood are as follows,
unless a greater distance is
specified by the manufacturer of
your cooking appliance:
450 mm
above electric hobs
and cookers
650 mm
above gas hobs
and cookers
650 mm
above an open grill or
deep fat fryer
See "Warning and Safety"
instructions for further information.
– When deciding on the safety distance
between the hob and cooker hood,
please note that a distance of 650
mm above electric cookers/hobs may
be preferable to give more working
space under the hood.
– Account should also be taken of the
height of the person who will be using
the hood most often. The person
should have sufficient space to work
comfortably at the hob, and also be
able to reach the hood controls with
ease.
– Please be aware that if positioned too
high, extraction will be inefficient.
– If you want the top of the cooker hood
telescopic extension piece to be
mounted flush with the ceiling, make
sure there is adequate space below
the appliance for working. See
maximum/minimum appliance height.
21