MECHANICAL STOPPER ADJUSTMENT

To adjust the stoppers you have to follow the scheme (Fig. 12).
To set the opening limit it's enough to fix the stopper (A) in the needed position by tightening
the 8mA screw with a n.13 key.
To obtain the desired closing limit you must adjust the stopper (B) (OPTIONAL) in the needed
position and tighten it as for stopper (A).

ELECTRICAL SAFETY DEVICES

The installation must be installed according to the current regulations and laws.
It is recommended that the following electronic control units be used:
- T2 for 1 or 2 single-phase PLUS.
For connections and technical data of accessories refer to the appropriate booklets.

CONNECTION TO THE POWER SUPPLY

In single-phase PLUS units, terminals 1-2-3 of the motor connector must be connected
respectively to terminals V-W-U of the control panel.
WARNING!
The length of connection cables from the motors to the control panel unit must not exceed
15 m.
The wire section of the motor power supply must be 2.5 mm
must be 0,75 mm
.
2

FORCE ADJUSTMENT

Single-phase PLUS require a T2 electronic control panel, equipped with electronic force
regulator.

MAINTENANCE

To be undertaken only by specialized staff after disconnecting power supply.
Lubricate the hinges and check the oil level and thrust force generated by the operator on
the gate once a year.
Lubricate the nut screw with silicon grease every two years.
6-1624020 rev. 14 21/07/2016