Miele PDR 910 G Panduan Memulai Cepat - Halaman 9

Jelajahi secara online atau unduh pdf Panduan Memulai Cepat untuk Pengering Miele PDR 910 G. Miele PDR 910 G 48 halaman. Commercial tumble dryer

- Chimneys or smokestacks that are in use.
- Shafts that are used to ventilate installation rooms with fireplaces.
- Flues that are used by third parties.
Smoke or exhaust gas that is fed back into the flue or shaft may be toxic.
Regularly check all components in the vent ducting (e.g. wall pipe, external grille, bends,
elbows, etc.) to make sure air can move through them and to ensure that they are working
properly. Clean components when necessary. Fluff deposits in the vent ducting system will
prevent the air from being extracted properly and, as a result, will stop the tumble dryer
from working properly.
If existing vent ducting is due to be used, it must be checked before being connected to
the tumble dryer.
Low pressure must not occur in the vent ducting.
There is a risk of suffocation and poisoning due to exhaust gases being sucked back if
gas-powered flow heaters, gas-powered room heaters, coal-burning stoves with a flue
connection, etc., are installed in the same room, in the same flat or in neighbouring rooms
and the negative pressure is 4 Pa or more.
The following measures for suitable room ventilation (examples) can help to prevent negat-
ive pressure in the installation area:
- Install vents that cannot be closed in the exterior walls.
- Use window switches so that the tumble dryer can only be switched on when a window
is open.
Please always seek approval from your building regulations inspector to confirm that the
appliance can be operated without risk and that negative pressure of over 4 Pa can be pre-
vented.
If multiple tumble dryers are to be connected to one vent ducting, a non-return flap must
be installed directly on the duct for each tumble dryer.
If this requirement is not observed, the tumble dryers may be damaged and their electrical
safety could be affected.
Follow the instructions in "Installation of the ducting".
Do not block the gap between the bottom of the tumble dryer and the floor with plinth
facings, deep pile carpet etc.
Ensure that no closeable door, sliding door or an oppositely hinged door is installed that
would hinder the drum door being opened in any way.
This tumble dryer is supplied with a special lamp to cope with particular conditions (e.g.
temperature, moisture, chemical resistance, abrasion resistance and vibration). This special
lamp must only be used for the purpose for which it is intended. It is not suitable for room
lighting. Replacement lamps may only be fitted by a Miele authorised technician or by the
Miele Customer Service Department.
Installing thermal shut-off equipment on site is recommended.
If gas-heated appliances are accessible to anyone, it is also necessary to check whether
a gas flow monitor needs to be used.
Warning and Safety instructions
9