Technical datasheet
Tumble dryer:
Heating:
Legend:
Optional extras:
Concrete base
Quality and density of concrete must comply with load.
BS
Concrete plinth must be firmly secured to floor!
Recommended height
Minimum height
Minimum width
Minimum depth
Machine connections:
Electrical
connection
Electrical connection must comply with national
regulations
If machines are hard-wired, a multi-pole main switch must
be provided on site.
A wall socket or main isolator must be accessible after
installation.
Equipotential
Connection with male thread
bonding
with washers and nut
Accessories not included.
If necessary, equipotential bonding with good galvanic
contact must be provided in accordance with all
appropriate national and local regulations.
Peak load
Control contact voltage
energy
Connection cable, min. cross-section
management
Connection cable to be ordered separately.
Connection via a flexible supply lead with a separate
isolator is recommended. The isolator should be visible
and easily accessible after machine installation.
Vented
Max. Nominal air flow in vented mode
Max. Permissible pressure loss
Connection on machine side (ext. diameter)
Connection pipe provided on site (int. diameter)
Max. temperature
As relative humidity inside the vent ducting can be as high
as 100%, suitable measures must be taken to prevent a
backflow of condensate into the machine.
Installation plan: PT 8807 EL
Date: 2015-Sep-15
Abbreviations in bold type:
Connection required
Abbreviations in circle with dashes:
Connection optional or required depending on model version
Voltage
Frequency
Rated load
Fuse rating
Connection cable, min. cross-section
Cable screw connector
Connection cable to be ordered separately.
PT 8807
Electric (EL)
en - US
4"
mm
100
2"
mm
50
47"
mm
1.200
55"
mm
1.400
V
3 AC 208
Hz
60
kW
27.4
3 × 90
A
mm²
AWG 16
M 50
mm
10 × 35
M
10
V
AC 230
mm²
5 × 1,5
m³/h
1.100
38,85 cu ft/h
Pa
300
0.04 PSI
6"
mm
150
6"
mm
150
°C
80
176 °F