Miele T 6551 Panduan Petunjuk Pengoperasian - Halaman 19

Jelajahi secara online atau unduh pdf Panduan Petunjuk Pengoperasian untuk Pengering Miele T 6551. Miele T 6551 28 halaman. Tumble dryers
Juga untuk Miele T 6551: Panduan Petunjuk Pengoperasian (32 halaman), Panduan Petunjuk Pengoperasian (26 halaman)

Miele T 6551 Panduan Petunjuk Pengoperasian
Reprogramming
Reprogramming possibilities
Program
ö
alterations
]
Reversing time*
in the Cottons
Programes 1 to 6
and Timed drying
programes 10 & 11
Reversing off /
Pause interval
in Cottons
programes 1 to 6
and Timed drying
programes 10 & 11
Residual moisture/
Prog. selection with the
Selector switch
Fan and heating
in pause times
Cooling down temperature
Vented air to
Reversing time*
in the Minimum iron
programes 7 to 9
Reversing off/
Pause interval
in Minimum iron
programes 7 to 9
without heating
Program 10
with heating
followed by Cooling down
Program 11
Additional display
during operation

Programmable residual moisture values

Program
1
2
A
3
4
5
6
7
B
8
9
The stored residual moisture values for the individual programs are shown in the additional display after the selector is
pressed. The sequence of the displayed residual moisture values for the programs is as follows:
B
8
B
7
A
6
A
5
/
,
/
,
/
,
/
M.-Nr. 05640910
Position of the
Program
Standard
selector
1 minute and
1
27 seconds
3
2
seconds
A
see chart
3
"Programmable
residual
moisture"
4
1
5
50
1 minute
6
27 seconds
3
7
seconds
B
15
8
minutes
20
9
minutes
C 0
0
!
T 6351
Options
Standard
Adjustable
- 4 %
- 3 % or - 5 %
- 2 %
- 1 or 0%
3 %
1 % or 5 %
13 %
8 % or 16 %
20 %
18 % or 22 %
26 %
24 % or 30 %
- 2 %
0 % or - 3 %
2 %
1 % or 4 %
8 %
5 % or 10 %
A
4
,
/
Options
WC
Bedd-
Adjustable
ing
25
25
20 seconds
secs
secs
to
2 minutes
10
0 (Off)
secs
or
2 to 10
seconds
0
0
0 or 1
o
C
40 °C
30 to 60
55
20 seconds
secs
to
2 minutes
0 (Off)
or
2 to 10
seconds
3 minutes
to
1 hour
3
3 minutes
mins
to
3 hours
2
0, 1 or 2
T 6551 / T 6751
Options
Standard
Adjustable
- 4 %
- 3 % or - 5 %
- 2 %
- 1 or 0%
3 %
1 % or 5 %
16 %
8 % or 13 %
22 %
18 % or 20 %
30 %
24 % or 26 %
- 2 %
0 % or - 3 %
2 %
1 % or 4 %
8 %
5 % or 10 %
19
Notes
*)Drum reverses to the left
and to the right in pro-
grammed timed intervals
Call up the residual moisture
values to be changed with
the selector switch and alter
with the start button.
1 = On
0 = Off
o
C
add to this cooling down
time to a cool temperature
o
of 50
C (Standard value).
0 = Residual moisture
(temperature display for
5 secs, after the selector
button is pressed)
1 = temperature only
2 = residual moisture only
Programme position is not
occupied.
Notes
A
3
A
2
/
,
/
,
Enter
program
changes
here
Enter
program
changes here
A
1
B
9
/
,
/
,