Miele CS 1122 Petunjuk Pengoperasian dan Pemasangan - Halaman 27

Jelajahi secara online atau unduh pdf Petunjuk Pengoperasian dan Pemasangan untuk Kompor Miele CS 1122. Miele CS 1122 40 halaman. Ceramic combiset
Juga untuk Miele CS 1122: Petunjuk Pengoperasian dan Pemasangan (40 halaman), Panduan Pengoperasian dan Instalasi (40 halaman), Petunjuk Pengoperasian dan Pemasangan (40 halaman), Petunjuk Pengoperasian dan Pemasangan (40 halaman), Petunjuk Pengoperasian dan Pemasangan (48 halaman), Panduan Pengguna (45 halaman)

Miele CS 1122 Petunjuk Pengoperasian dan Pemasangan
Safety distance from the wall covering
If a wall covering is installed, a minimum safety distance must be maintained
between the countertop cut-out and the covering, since high temperatures can
damage these materials.
If the covering is made of a combustible material (such as wood), the distance
between the countertop cut-out and the wall covering must be a minimum of
2" (50 mm).
For coverings made of non-combustible materials (such as metal, marble, granite
or ceramic tiles) the minimum safety distance e between the countertop cut-out
and the wall covering must be 2" (50 mm) minus the thickness of the covering.
For example: thickness of wall covering 9/16" (15 mm)
2" (50 mm) - 9/16" (15 mm) = minimum safety distance 1 3/8" (35 mm).
a Wall frame
b Wall covering
x = thickness of the wall covering
c Countertop
d Countertop cut-out
e Minimum safety distance
with flammable materials 2" (50 mm)
with non-flammable materials 2" (50 mm) minus x

Installation

27