Miele CS 1223 Petunjuk Pengoperasian dan Pemasangan - Halaman 34

Jelajahi secara online atau unduh pdf Petunjuk Pengoperasian dan Pemasangan untuk Kompor Miele CS 1223. Miele CS 1223 48 halaman. Induction wok
Juga untuk Miele CS 1223: Petunjuk Pengoperasian dan Pemasangan (40 halaman), Petunjuk Pengoperasian dan Pemasangan (44 halaman), Petunjuk Pengoperasian dan Pemasangan (40 halaman), Petunjuk Pengoperasian dan Pemasangan (44 halaman)

Miele CS 1223 Petunjuk Pengoperasian dan Pemasangan
Safety instructions for installation
Safety distances to the sides of the
appliance
Ideally the appliance should be
installed with plenty of space on either
side. There may be a wall at the rear
and a tall unit or wall at one side. On
the other side, however, no unit or
divider should stand higher than the
built-in appliance (see illustrations).
Due to the high temperatures radiated
by the appliance, it is essential that a
minimum distance of 50 mm is
maintained between the worktop
cut-out and the back wall.
The following minimum distance a
between the worktop cut-out and a wall
or tall unit to the right or left of it must
be maintained:
40 mm
for
CS 1212 / CS 1212-1
CS 1221 / CS 1221-1
CS 1222
CS 1223
CS 1234 / CS 1234-1
50 mm
for
CS 1112
CS 1122
CS 1134
CS 1326
CS 1327
CS 1411
100 mm for
CS 1012 / CS 1012-1
150 mm for
CS 1421
CS 1312
CS 1322
200 mm for
CS 1034 / CS 1034-1
250 mm for
CS 1011
CS 1021
34
Recommended
Not recommended
Not allowed