Miele GAS COMBISET CS 1012 Petunjuk Konversi - Halaman 10
Jelajahi secara online atau unduh pdf Petunjuk Konversi untuk Kompor Miele GAS COMBISET CS 1012. Miele GAS COMBISET CS 1012 40 halaman. Double gas combiset
Juga untuk Miele GAS COMBISET CS 1012: Petunjuk Pengoperasian dan Pemasangan (44 halaman), Petunjuk Pengoperasian dan Pemasangan (44 halaman), Dimensi Produk (4 halaman)
Converting CS 1012
To convert the burners
,
Conversion to a different type of
gas should only be performed by an
authorized gas technician.
Turn off the main gas supply (if the
appliance has been installed) and
disconnect the appliance from the
main electrical power supply before
proceeding.
When converting to a different type of
gas, the jets and needle valves have to
be changed.
Maximum output
Gas type
Normal
Natural Gas
burner
LP Gas (Propane)
Fast
Natural Gas
burner
LP Gas (Propane)
Total
Natural Gas
output
LP Gas (Propane)
Minimum output
Gas type
Normal
Natural Gas
burner
LP Gas (Propane)
Fast
Natural Gas
burner
LP Gas (Propane)
10
The following jets and needle valves
should be installed into their respective
burners. Follow codes accordingly.
Natural gas
Normal
burner
Fast
burner
LP Gas (Propane)
Normal
burner
Fast
burner
BTU/hr
kW
5,700
1,65
5,000
1.45
10,600
3.10
9,300
2.75
16,300
4.75
14,300
4.2
BTU/hr
kW
775
0.227
1,010
0.296
1,550
0.454
1,500
0.439
Code Jet size
Code
(Ø mm)
110
1.10
42
150
1.50
60
68
0.68
29
92
0.92
40
Needle
valve size
(Ø mm)
0.42
0.60
0.29
0.40