Connections
Connection
Connector
Mains
IEC 60320 C18
Battery
Customer specific
Mating type
Mains cable IEC 60320 C17
Customer specific
EN
Selectable charging characteristics
The desired charging characteristics can be selected by means of the
DIP-switches on the backside of the device. Use below chart to select the
desired charging characteristics. A label with all available characteristics
and the necessary DIP-switch settings can be found near the switches on
the device.
DIP-switch settings
Selected characteristic
0000
Selection of the charging charateristics is done via an
interface (USB, I
1
2
3
4
software
1000
Characteristic IUIaU for Exide Gel traction batteries with
24 V (12 cells), C5 = 50 ... 76 Ah
1
2
3
4
0100
Characteristic IUIaU for Discover AGM batteries with
24 V (12 cells), C5 = 55 Ah
1
2
3
4
1100
Characteristic IUIaU for Optima Yellow Top or Blue Top
batteries with 24 V (12 cells), C5 = 50 ... 65 Ah
1
2
3
4
0010
Characteristic IUIaU for wet batteries with 24 V
(12 cells), C5 = 50 ... 76 Ah
1
2
3
4
1010
Characteristic IUIaU for standby operation
with 24 V (12 cells), C5 = 50 ... 76 Ah
1
2
3
4
0110
Power supply mode with 24 V, 10 A
1
2
3
4
1110
Power supply mode with 28.2 V, 5 A
1
2
3
4
0001
Power supply mode with 28.2 V, 10 A
1
2
3
4
1001
Individual customer characteristic
1
2
3
4
0101
Individual customer characteristic
1
2
3
4
1101
Individual customer characteristic
1
2
3
4
0011
Individual customer characteristic
1
2
3
4
1011
Individual customer characteristic
1
2
3
4
0111
Individual customer characteristic
1
2
3
4
1111
Individual customer characteristic
1
2
3
4
C or CAN) using a configuration
2
EN