Miller Axcess 675 Panduan Pemilik - Halaman 24

Jelajahi secara online atau unduh pdf Panduan Pemilik untuk Sistem Pengelasan Miller Axcess 675. Miller Axcess 675 48 halaman. Automatic welding interface and arc welding power source
Juga untuk Miller Axcess 675: Panduan Pemilik (48 halaman)

NOTE

4-4. Using Multiple Welding Power Sources

6
6
Current Flow Path
OM-217 751 Page 20
Welding on a single workpiece using multiple welding power sources can cause
arc blow and arc impedance to develop or intensify.
1
3
2
4
7
5
Gun
Travel
3
2
4
1
2
3
4
5
6
7
Each welding power source should
have a separate work cable connection
to the workpiece. Do not stack or join
work cables together at the workpiece.
This is very important for pulse welding
applications.
It is important to connect the voltage
sensing lead as near to the weld as
possible, but not in the return current
path.
Connect voltage sensing lead at the end
of the weld joint.
The direction of the welding path should
be
connections.
Connect work clamp at the beginning of
the weld joint.
Each welding gun should have its own
5
source of shielding gas. Use a separate
1
shielding gas regulator and shielding
gas connection for each welding gun.
Arc blow is the deflection of a welding
arc from its normal path due to magnetic
forces. It will adversely affect the
appearance of a weld, cause excessive
spatter, and impair the quality of a weld.
Arc blow occurs primarily during the
welding of steel or ferromagnetic
metals. Weld current will take the path of
least resistance, but not always the
most direct path through the workpiece
to the work lead connection. The most
intense magnet force will be around the
arc due to a difference in resistance for
the magnetic path in the base metal.
The work clamp connection is important
and should be placed at the starting
point of a weld. It is recommended to
have as short of an arc as possible so
that there is less of an arc for the
magnetic forces to control. Conditions
affecting the magnetic force acting on
the arc vary so widely that the reference
here is only about cabling connections
and arc preferences.
Welding Power Source
Electrode Cable
Feeder Cable
Work Cable
Voltage Sensing Lead
Wire Feeder
Workpiece
away
from
the
work
cable
804 638-A