3-14. Electrical Service Guide
Input Voltage
Input Amperes At Rated Output
Max Recommended Standard Fuse Rating In Amperes
Time-Delay
Normal Operating 3
Min Input Conductor Size In AWG 4
Max Recommended Input Conductor Length In Feet (Me-
ters)
Min Grounding Conductor Size In AWG 4
Reference: 1999 National Electrical Code (NEC)
1 Consult factory for circuit breaker applications.
2 "Time-Delay" fuses are UL class "RK5" .
3 "Normal Operating" (general purpose - no intentional delay) fuses are UL class "K5" (up to and including 60 amp), and UL class "H" ( 65 amp and
above).
4 Conductor data in this section specifies conductor size (excluding flexible cord or cable) between the panelboard and the equipment per NEC Table
310.16. If a flexible cord or cable is used, minimum conductor size may increase. See NEC Table 400.5(A) for flexible cord and cable requirements.
380
149
1
2
175
225
398 (121)
Three-Phase, 50/60 Hz
400
415
141
136
175
150
200
200
1/0
1/0
1/0
441 (134)
474 (145)
4
6
6
Three-Phase, 60 Hz
500
460
575
114
124
100
125
150
110
175
175
150
2
1
3
490 (149)
482 (147)
548 (167)
6
6
6
OM-2221 Page 17