8-4.

V-Sense Feeder Welding Mode - GMAW/FCAW/FCAW-S Output ON

10
11
Weld terminals are energized at all
times in V-Sense Feeder welding
mode.
1 Mode Switch
2 Volts Indicator
3 Left Display
4 Right Display
5 Adjust Control
6 Arc Control Indicator For Wire Modes
7 Arc Control Indicator
8 Arc Control Button
9 Arc Control Soft Indicator
10 Remote In Use Indicator
11 Remote 14 Receptacle
Setup
For typical system connections refer to Sec-
tion 8-3.
Set Mode Switch to FCAW-S NO GAS, or
GMAW/FCAW GAS, OUTPUT ON position.
The Left Display toggles between actual
voltage and preset arc voltage with the Volts
indicator lit.
OM-292663 Page 32
3
2
7
Ref. 273528-B
Operation
The Adjust Control is used to set desired
preset voltage.
The Left Display toggling momentarily
pauses while the preset voltage is
adjusted.
If a remote control is connected to the Re-
mote 14 Receptacle and used for voltage
adjustment, the adjustment will have full
range of preset voltage. The Remote In Use
indicator will be lit.
. If an ArcReach device is used for volt-
age adjustment, it will have full range
of the preset voltage. Dependent on
the capabilities of the device, it may
have the ability to override parameter
adjustments and mode switch setting.
The Remote In Use indicator will be lit.
An ArcReach device will override a re-
mote control connected to the Remote
14 Receptacle.
Pressing the Arc Control button allows ad-
justment of Arc Control settings.
5
4
6
9
8
1
Arc Control
Pressing the Arc Control button will cause
the Arc Control indicator to light. Dependent
on the setting: the STIFF or SOFT indicator
will light and STIF or SOFT will appear on
the Left Display. 0 to 25 will appear on the
Right Display. If set to 0 neither STIF or
SOFT will appear.
Rotate Adjust Control to select desired Arc
Control setting from 0 to 25 Soft and 0 to 25
Stiff. Minimum Arc Control setting is Soft 25.
Maximum Arc Control setting is Stiff 25. Mid-
range adjustment of 0 is good for most appli-
cations. Use lower Arc Control settings to
stiffen the arc and reduce puddle fluidity.
Use higher Arc Control settings to soften the
arc and increase puddle fluidity.
After three seconds of inactivity the Adjust
Control will revert back to adjusting preset
voltage.