Miller SUITCASE 12RC Panduan Pemilik - Halaman 22

Jelajahi secara online atau unduh pdf Panduan Pemilik untuk Aksesori Pengelasan Miller SUITCASE 12RC. Miller SUITCASE 12RC 40 halaman. Wire feeder with gun and meters
Juga untuk Miller SUITCASE 12RC: Spesifikasi (2 halaman), Panduan Pemilik (36 halaman), Panduan Pemilik (40 halaman)

Miller SUITCASE 12RC Panduan Pemilik

6-1. Controls

Internal Side View
OM-263984 Page 18
SECTION 6 − OPERATION
1
2
3
4
5
Front Panel
7
JOG
Internal Control Panel
1
Power Control Switch
2
Trigger Hold Switch
(If applicable)
Depress the switch to On to weld
without holding gun trigger through-
out the weld cycle.
To start weld, press and release gun
trigger. To end weld, press and re-
lease gun trigger.
Depress the switch to Off to turn trig-
ger hold Off.
3
Meter Display (If applicable)
4
Volts, Wire Feed Speed Or
Amps Select Switch
(If applicable)
.
Meter is factory set to display
voltage and wirefeed speed. To
display voltage and amps refer to
Section 6-2 for DIP switch set-
tings.
5
Voltage Control
6
6
Wire Speed Control
Use control to adjust wire speed.
7
Purge Switch
Press switch to momentarily energize
gas solenoid and purge air from gun,
and to adjust shielding gas regulator.
8
Jog Switch
Use Jog position to momentarily feed
welding wire at speed set on Wire
Speed control without energizing
welding circuit or shielding gas valve.
Close and latch door.
8
Ref. 263 838-A / 804 213-B / 263 250-A