4.2 Operating principles

C
3/2-way valve
Normally inlet port 1 (P/NC) closed, outlet port 2
(A/OUT) conected with exhaust port 3 (R/NO).
C
3/2-way valve for vacuum*, with auxiliary
control air
Normally inlet port 1 (P/NC) closed, outlet port 2
(A/OUT) conected with exhaust port 3 (R/NO).
D
3/2-way valve
Normally inlet port 1 (P/NO) connected with
outlet port 2 (B/OUT), exhaust port 3 (R/NC)
closed.
H
5/2-way valve
Normally inlet port 1 (P) connected with outlet
port 2 (A), outlet port 4 (B) connected with
exhaust port 5 (S), exhaust port 3 (R) closed.
Z
5/2-way valve
Pulse version (2 coils)
6
english
L
5/3-way valve
Middle position all port connections closed,
inlet port 1, outlet port 4 and 2, vent of outlet
ports to 5 respectively 3.
N
5/3-way valve
Middle postion pressure inlet port 1 (P) closed,
outlet ports 2 (A) and 4 (B) connected with
exhaust ports 3 (R) respectively 5 (S).