8.2 Malfunctions
If malfunctions occur, check whether:
• the device has been installed according to the instructions,
• the electrical and pneumatic connections are correct,
• the device is not damaged,
• all screws have been tightened,
• the voltage and pressure have been switched on,
• the pipelines are clean.
Valve does not switch
Possible causes:
• short circuit or coil interrupted,
• core or core area dirty,
• medium pressure outside the permitted pressure range.
Valve does not close
Possible causes:
• inner compartment of the valve is dirty.
14
english
9
SPARE PARTS
CAUTION!
Risk of injury and/or damage by the use of incorrect parts!
Incorrect accessories and unsuitable spare parts may cause injuries
and damage the device and the surrounding area.
▶ Use original accessories and original spare parts from Bürkert only.

9.1 Ordering spare parts

When ordering spare parts, quote the number of the spare part set
(SET 1, SET 2, SET 3 – see "Fig. 7: Spare part sets", page 15) as
well as the order number of your complete device.