ATLAS THE ALS SIMULATOR P75
To change the IV pads and the IO insert, remove them from their original position and disconnect them from the drainage system. Then connect the
replacement to the drainage system and place the new training pad in the slot. At the end of the training session, we recommend drying, removing the
cannulas, and taking the drainage system apart.
When the day's sessions are done, flush the IV and IO sites with air to remove any fluid/liquid in the system. Connect a syringe filled with air to the IV/IO
catheter and flush the IV pads/IO insert with air until only air exits the overflow tube.
Replacement of IV sites
Replacement of IO site
10
ATLAS THE ALS SIMULATOR P75 | Circulation