the position of two of the three phase
wires (black, gray or brown) in the plug.
2.3.5 - Electrical connection modification
Unless otherwise specified, the slicers are equipped with 400 V. three-phase
connection. To modify the connection carefully follow these instructions:
remove the plug from the electric network;
-
turn the slicer on the side opposite the trolley;
-
take off the yellow cover from the electrical box;
-
remove the motor cables from the electronic card;
-
connect wires from the motor that have the same colour (white-white, blue-
-
blue, etc.);
reconnect them to the electronic card;
-
check the positioning of the feed selection plugs on the electronic card (Fig. n°
-
21);
close the box, reposition the slicer and proceed as in par. 2.3.3.
-
2.4 - ELECTRICAL DIAGRAM - 230V. SINGLE-PHASE - 230V.
THREE-PHASE - 400V. THREE-PHASE, 'SIDNEY' PUSH-BUTTON
Fig. n°20
Fig. n°21
10
2.4.1 - Single-phase 230 V. tension selection
OUTPUT DIAGRAM
2.4.2 - Three-phase 230 V. tension selection
2.4.3 - Three-phase 400 V. tension selection