NOTE!
The stop-valve is not suitable for precise dosing.
4. After the filling process, turn the discharge tube
with the opening showing upwards to prevent
escaping liquids.
Troubleshooting
Problem
The instrument does not
generate an overpressure
Instrument is not pum-
ping any liquid
To eliminate the error
1. Stop-valve is opened.
2. The instrument is not connected with the container to form a seal.
1. The instrument is not connected with the container to form a seal.
2. The riser pipe does not extend into the liquid being filled.
Completing filling and dismounting
CAUTION!
The container is under pressure. Bodily injury due
to escaping liquid.
`
`
Slowly remove the instrument from the container.
1. Screw off the discharge tube and remove the hand
pump ball from the bung.
2. Carefully remove the instrument from the container.
3. Rinse the instrument with a pH-neutral fluid.