13) CONTROL DEVICES (Fig. M)
a – On/Off switch
b – Light
c – Controller
14) PERIODICAL MAINTENANCE AND CLEANING
We suggest to carry out a daily/weekly cleaning of the external
parts of the equipment and a monthly thorough cleaning of the
internal parts of the refrigerated cabinet for the good working,
the good preservation of the food and the aesthetics preservation
of the equipment. The cleaning has to be made by qualified
people, who should know the procedure described in this
paragraph.
Attention! Before starting any cleaning operation it is necessary
to turn off the equipment by the on/off red switch and to unplug
or disconnect the equipment by the general power security switch
of your shop.
OBLIGATION
IMPORTANT – DURING THE WHOLE CLEANING
OPERATION USE WORKING GLOVES OF CLASS II
TO PROTECT YOUR HANDS ALL THE TIME AND
THE PERSONAL PROTECTIVE EQUIPMENT
ACCORDING TO THE LAW OF YOUR COUNTRY.
Remove all goods from the cabinet and keep them in a fridge or
in a refrigerated ambient suitable for their preservation.
Carefully and thoroughly clean the display surface, the glasses,
the aluminium profiles, the door gaskets (if presents) with
specific cleaners for any surface.
PROHIBITION
Do not use acid and alkaline detergents, chemical /
organic solvents, unknown chemical composition
detergents. During the maintenance and cleaning it is
forbidden to use abrasive substances and/or sharp
tools which can damage the unit (fig. N).
After every cleaning operation it is necessary to rinse with warm
water and dry the unit with a soft and clean cloth.
In case of long absences (i.e. holidays etc.) the unit has to be
unplugged, emptied completely, cleaned and dried. Make sure
to leave the doors open to prevent bad smells.
A correct maintenance of the equipment can considerably
prolong its life.
15) TECHNICAL ASSISTANCE (servicing)
ATTENTION
If the equipment does not run properly or does not work
at all, in your own interest before calling for servicing, we
suggest to check the following points:
- if the plug is well inserted in the socket;
- if the power reaches the socket to which the equipment
is connected;
- if the network voltage is the same as requested for the
equipment (+-6%).
16) REPLACEMENT OF LAMPS
The replacement and the substitution of lamps must be made by
qualified technician and when the unit is disconnected from the
power net.
Before replacing the lamp disconnect the equipment by the
general power supply. During the whole replacement operation
use proper working gloves.
17) EMERGENCY SITUATIONS
Devices to be used in case of fire: powder-extinguishers or
liquid-extinguishers complying with the current legislation.
18) DISMANTLING THE UNIT
OBLIGATION
The unit must be disposed of in accordance with your
country's waste management legislation.
OBLIGATION
IN CASE OF REQUEST FOR SERVICE, CONTROL
AND/OR REPLACEMENTS YOU WILL HAVE TO
CONTACT THE SUPPLIER WHERE THE CABINET
WAS BOUGHT.