Cascading Multiple ALARMS-xx
via RS422
Once the first ALARMS-xx has been connected to the AM-xx / MADI-xx, any additional alarm units
may be cascaded from the first, by means of a pin-to-pin RS422 cable. The 'DATA OUT' port of the
first unit is connected to the 'DATA IN' port of the second unit. Alarm data for all AM-xx / MADI-xx
channels is passed by these ports, so it is only necessary to set the ALARMS-xx DIP switch to the
desired channel group.
Refer to the following table for details of the connections for cascading additional ALARMS-xx units
(serial ports are all female 9-pin D-Sub types):
Signal
GND
RX+/RX-
TX+/TX-
RX-/RX+
TX-/TX+
Notes:
1) If required, the same alarm status information may be relayed to different areas via multiple
ALARMS-xx units by setting the DIP switches of cascaded units to the identical channel groups.
2) All ALARMS-xx units in the same system must be connected either via RS422 or LAN and not by a
combination of the two methods.
© 2009 Michael Stevens & Partners Ltd
ALARMS-xx
ALARMS-xx DATA IN
4, 5, 9
2
3
7
8
3
ALARMS-xx DATA OUT
4, 5, 9
2
3
7
8
Version 1.0