TROUBLESHOOTING
Problem: Water does not get hot
1. Make sure the power supply is on and working.
2. If light does not come on, check that the reset button is pushed in; follow steps from previous
section.
3. If the indicator light is illuminated, but water temperature does not get hot at the sink, test for
a plumbing crossover as follows; shut off cold water supply to water heater and open hot
water tap. There should be no water flowing. Any continuous flow indicates a cross over
which will effect the temperature and will need to be corrected.
4. If there is no crossover, then replace the heating element (see previous sections).
Problem: Indicator light not on
1. If the light does not come on, but water gets hot, check for faulty indicator light.
2. Check reset button; follow steps from previous section.
Problem: Brown water
1. Brown or rusty water indicates a "spent" anode rod. Replace anode rod.
Problem: Odor in water
1. Smelly water could be due to an unusual reaction between local water and the heater's
anode rod. Check anode rod.
Problem: Water is too hot
1. Turn the temperature knob counter clockwise to a lower temperature setting. If temperature
does not lower within 60 minutes, then replace thermostat.
Problem: Water is not hot enough
1. Under Instructions for Use, see "Setting the thermostat".
Problem: Water is leaking
1. Turn off power switch and unplug water heater from 110 VAC outlet.
2. Check water fittings and T&P fitting in the top of the tank.
3. Remove cover and inspect heating element gasket