Diamond 60/60 PCE Series Instalasi - Penggunaan - Pemeliharaan - Halaman 15

Jelajahi secara online atau unduh pdf Instalasi - Penggunaan - Pemeliharaan untuk Oven Diamond 60/60 PCE Series. Diamond 60/60 PCE Series 19 halaman. Range, gas solid top
Juga untuk Diamond 60/60 PCE Series: Panduan Memulai Cepat (13 halaman)

22. CONVERSION TO ANOTHER TYPE OF
GAS
See Chapter " Instructions for installation ".

23. COMMISSIONING

See Chapter " Instructions for installation ".

24. TROUBLESHOOTING

GAS HOB
THE MAIN BURNER DOESN'T TURN ON
Possible causes:
-
Insufficient gas supply pressure.
-
Blocked tubing or nozzle.
-
Defective gas tap or valve.
-
Defective burner (gas outlet holes clogged).
GAS SOLID TOP RANGES
THE PILOT BURNER DOES NOT LIGHT.
Possible causes:
-
Insufficient gas supply pressure.
-
Blocked tubing or nozzle.
-
Defective gas tap or valve.
-
Igniter defective or not properly connected.
-
Igniter or igniter wire defective.
PILOT BURNER GOES OUT DURING USE.
Possible causes:
-
Insufficient gas supply pressure.
-
Defective gas tap or valve.
-
Defective thermocouple or insufficient heating.
-
Thermocouple incorrectly connected to gas tap or
valve.
-
Knob of gas tap or valve not pressedsufficiently.
THE MAIN BURNER DOES NOT LIGHT (EVEN
THOUGH PILOT IS LIT).
Possible causes:
-
Insufficient gas supply pressure.
-
Blocked tubing or nozzle.
-
Defective gas tap or valve.
-
Defective burner (gas outlet holes clogged).
GAS OVEN
THE MAIN BURNER DOESN'T TURN ON
Possible causes:
-
Insufficient gas supply pressure.
-
Blocked tubing or nozzle.
-
Defective gas tap or valve.
-
Defective burner (gas outlet holes clogged).
HEATING CANNOT BE ADJUSTED.
Possible causes:
-
Defective gas tap
GAS STOCKPOT STOVE
THE PILOT BURNER DOES NOT LIGHT.
Possible causes:
-
Insufficient gas supply pressure.
-
Blocked tubing or nozzle.
-
Defective gas tap or valve.
-
Igniter defective or not properly connected.
-
Igniter or igniter wire defective.
PILOT BURNER GOES OUT DURING USE.
Possible causes:
-
Insufficient gas supply pressure.
-
Defective gas tap or valve.
-
Defective thermocouple or insufficient heating.
-
Thermocouple incorrectly connected to gas tap or
valve.
-
Knob of gas tap or valve not pressedsufficiently.
THE MAIN BURNER DOES NOT LIGHT (EVEN
THOUGH PILOT IS LIT).
Possible causes:
-
Insufficient gas supply pressure.
-
Blocked tubing or nozzle.
-
Defective gas tap or valve.
-
Defective burner (gas outlet holes clogged).
17