USE & CARE
12
Cleaning the Quartz Sleeve
7. Remove the Quartz Sleeve and O-Ring by gently twisting and pulling the
sleeve. It's recommended that you use cotton gloves during this step.
8. Using a soft, lint-free cloth or towel wipe the sleeve down using a
commercial scale cleaner (i.e. CLR® or LIME-A-WAY
scaling or iron deposits that may be on the outside of the Quartz Sleeve.
WARNING
9. Replace the O-Ring and slide the Quartz Sleeve into the Reactor.
Follow steps 5 and 6 in the manual to complete installation.

OPERATING THE CONTROLLER

Aquasana UV Filters come with a featured controller that includes an LED
visual screen with audible warnings in a water-tight case.
Even though the UV system has a visual and audible warning built into
the Controller, a green LED does not necessarily indicate that the water
coming from this system is in fact potable (safe to drink). These systems
do not measure the level of disinfection; they simply measure the "on-off"
status of the UV Lamp. Please have your water checked for microbiological
contaminants on a regular basis.
While the LED is red and the buzzer is sounding the water from the system should
NOT be consumed. If any water does pass through the system during this period,
please follow the disinfection procedure as outlined in this manual before the water
is consumed.
These systems feature a tricolor LED that indicates system
status and a 4-digit display to indicate UV Lamp life remaining.
Pressing the button will change the display to indicate total
running time.
• Green LED: UV Lamp is on and within operating range
• Red LED & Audible Buzzer: UV Lamp is not on
or UV Lamp life has expired
To remedy this condition, an expired UV Lamp must
be replaced with a new genuine Aquasana UV Lamp.
See the data plate located on the UV Reactor for
replacement model numbers.
(Cont. from previous page)
DO NOT get any moisture or liquids inside the Quartz Sleeve.
WARNING
). This removes
®