AquaStar 32CDAVV SERIES Panduan Petunjuk Instalasi - Halaman 8
Jelajahi secara online atau unduh pdf Panduan Petunjuk Instalasi untuk Peralatan Pencahayaan AquaStar 32CDAVV SERIES. AquaStar 32CDAVV SERIES 20 halaman. Channel drain, submerged, suction, single, unblockable outlet instructions
MANUFACTURED SUMP INSTALLATION (BOOSTER & CIRCULATING PUMP INSTALLATION)
IMPORTANT
• Models: 32CDFLxxx, 32 CDAVxxx,
32CDFLVxxx, 32FLACxxx,
32CDAVVxxx, 32CDAVACxxx,
32CDBTxxx, 32CDLTxxx, 32CDLTVxxx,
32CDPHxxx, 32CDPHVxxx,
32CDPHTSxxx (AV=Anti-Vortex)
• Single or multiple drain or pipe use
• At IAPMO (a nationally recognized
testing lab), all AquaStar channel
drains have been tested to
three inches in sump depth –
field-fabricated or manufactured
• All AquaStar channel drains are
VGB 2008 compliant
• Plumbing to one or two pumps plus
skimmer equalizer are approved –
DO NOT exceed maximum flow rate
of outlet cover for total system
• One-, two- or three-pipe connections
are approved at any port or
configuration under manufactured
sump or field-fabricated sump
• Any plumbing configuration is
approved but do not exceed
maximum flow rate
MANUFACTURED SUMP INSTALLATION (DUAL PUMP WITH
HYDROSTATIC VALVE INSTALLATION)
IMPORTANT
• Models: 32CDFLxxx, 32 CDAVxxx,
32CDFLVxxx, 32FLACxxx,
32CDAVVxxx, 32CDAVACxxx,
32CDBTxxx, 32CDLTxxx, 32CDLTVxxx,
32CDPHxxx, 32CDPHVxxx (AV=Anti-
Vortex)
• Single or multiple drain or pipe use
• At IAPMO (a nationally recognized
testing lab), all AquaStar channel
drains have been tested to
three inches in sump depth –
field-fabricated or manufactured
• All AquaStar channel drains are
VGB 2008 compliant
• Plumbing to one or two pumps plus
skimmer equalizer are approved –
DO NOT exceed maximum flow rate
of outlet cover for total system
• One-, two- or three-pipe connections
are approved at any port or
configuration under manufactured
sump or field-fabricated sump
• Any plumbing configuration is
approved but do not exceed
maximum flow rate
8
AV STYLE OR FLAT GRATE
(32CDAV) (32CDFL)
INTERIOR
POOL FINISH
EARTH
GRAVEL
CIRCULATING PUMP
1-1/2", 2", 2-1/2",
3" OR GREATER PIPE
For additional information on proper drain installation refer to The Association of Pool &
Spa Professionals ANSI/APSP-7 Standard and the U.S. Consumer Product Safety Commission
Guidelines for Entrapment Hazard.
AV STYLE OR FLAT GRATE
(32CDAV) (32CDFL)
INTERIOR
POOL FINISH
EARTH
GRAVEL
877.768.2717 fax 877.276.POOL Outside the U.S.: 1.805.620.5060 fax +1.949.336.1940
fig. 4
MANUFACTURED
SUMP INSTALLATION
(BOOSTER & CIRCULATING PUMP INSTALLATION)
OPTIONAL HYDROSTATIC VALVE
fig. 5
MANUFACTURED
SUMP INSTALLATION
(DUAL PUMP WITH HYDROSTATIC VALVE INSTALLATION)
PUMP #1
1-1/2", 2", 2-1/2",
3" OR GREATER PIPE
FRAME / MUD-RING
SHOTCRETE / GUNITE
BOOSTER PUMP
1-1/2", 2", 2-1/2",
3" OR GREATER PIPE
OPTIONAL HYDROSTATIC VALVE
FRAME / MUD-RING
SHOTCRETE / GUNITE
PUMP #2
1-1/2", 2", 2-1/2",
3" OR GREATER PIPE