AQUASTREAM ABSC02787 Panduan Pemasangan, Pengoperasian & Pemeliharaan - Halaman 9

Jelajahi secara online atau unduh pdf Panduan Pemasangan, Pengoperasian & Pemeliharaan untuk Inverter AQUASTREAM ABSC02787. AQUASTREAM ABSC02787 20 halaman.

Residential Steambath Generator Systems

Electrical Specifications

All electrical wiring to be installed by a qualified licensed electrician in accordance with National
E lectrIcal Code and local electrical code.
Power Wiring
See " Field Power Wiring" Diagrams (Page 8)
1. Check power voltage. Use 240V/ 1ph to connect S H
2. Use minimum 90ºC /600V rated insulated copper conductors only for field wiring, sized in accordance
with National E lectrical Code and local electrical code for the Amps in Ampere Chart.
3. Connect suitably sized equipment grounding wire to ground terminal provided.
4. Install a separate circuit breaker between supply and unit. Provide a power supply disconnect
within sight of the steam generator or one that is capable of being locked in the open position.
____________________________________________________________ __
____________________________________________________________ __
Maximum Room
Model No.
Volume ft
_______________________________________________________________________________________
ABSC02787
225(6.37)
_______________________________________________________________________
ABSC02789
360 (10.19)
__________________________________________________________________________
ABSC02782
575 (16.82)
_________________________________________________________________________

Wiring Diagrams

Diagram
for ABSC02787
ABSC02789
Diagram
for ABSC02782
!
caution
TO AVOID EQUIPMENT DAMAGE DO NOT
CONNECT POWER SUPPLY DIRECTLY TO
HEATING ELEMENTS !!!
a qu as te a m
Ampere Chart
Voltage/
3
(m
2
)
KW
phase
7.5
240/1
9.0
240/1
12
240/1
POWER INPUT
L1
L2
G
BLACK
BLACK
GREEN
GROUND
WHITE
C
LIGHT
BLUE
CONTACTOR
S
WATER
FEED
SOLENOID
HEATING
VAVLE
ELEMENT
POWERINPUT
L2
L1
BLACK
BLACK
GREEN
PURPLE
FUSES
GROUND
C
CONTACTOR
S
WATER
FEED
SOLENOID
HEATING
VALVE
ELEMENT
residential steambath generator.
Wire Size
Amperes
AWG (mm
32
8 (10)
38
8 (10)
50
6 (16)
TRANSFORMER
WHITE
DARK
BLUE
PURPLE
TO PROBE
WHITE
GRAY
CONTROL BOARD
TRANSFORMER
WHITE
DARK
BLUE
PURPLE
TO PROBE
WHITE
LIGHT
BLUE
WHITE
GRAY
CONTROL BOARD
2)
L E G E N D
(
All Diagrams)
FIELD
WIRING
FACTORY
WIRING
AUTOMATIC DRAIN
(optional)
L E G E N D
(All Diagrams)
FIELD
WIRING
FACTORY
WIRING
Automatic Drain
(optional)
7
aquabrass.com