AQUASYSTEM AMH1-25SUS Panduan Pengoperasian - Halaman 8

Jelajahi secara online atau unduh pdf Panduan Pengoperasian untuk Pompa Air AQUASYSTEM AMH1-25SUS. AQUASYSTEM AMH1-25SUS 12 halaman. Air-motor type centrifugal pump

AQUASYSTEM AMH1-25SUS Panduan Pengoperasian
In the below case happens,
1. For no rotating or no discharging, make sure first,
● If the pressure to pump is kept between 0.4~0.6 MPa?
● If the air valve is fully open?
● If air hose is firmly connected?
● If air leakage is not found from the connecting portions
such as the pipe and hose?
● If the pipe condition is dry, which requires the prime water(P. 6)?
2. For poor discharging volume, make sure first
● If the pressure to pump is kept between 0.4~0.6 MPa?
● If the air valve is fully open?
● If liquid viscosity is less than 2,000 cP?
● If air leakage is not found from the connecting portions
such as the pipe and hose?
3. For any leakage, make sure first,
● If any consumable parts such as oil seal or packing etc. are
regularly and properly replaced (P. 7).
Contact us for any assistance.
※ In case any unusual case, or improper case on the pressure,
the discharging volume, the vibration and/or noise is found,
immediately stop the operation, and contact our sales/service
shops or us (P. 13). Do not disassemble the product at customers
site, which automatically results in invalidity of our assurance.
Maintenance and Inspection
1. Every 300 operation hours, remove motor case (Part No.9 in P. 11),
and fill heavy duty grease through the nipple (Part No.55 in P.11).
Also, make sure to remove anything oily adhered to motor case.
2. In case liquid leakage is found from the lower portion of air-motor,
we do advise the oil seal should be replaced.
Contact us, a dealer or a retailer for the replacement.
7