Juga untuk HP 316095-B21 - StorageWorks Edge Switch 2/24: Manual Pembaruan (9 halaman), Manual (41 halaman), Manual (40 halaman), Catatan Rilis (32 halaman), Manual (26 halaman), Catatan Rilis (27 halaman), Catatan Rilis (25 halaman), Panduan Petunjuk Instalasi (24 halaman), Catatan Rilis (23 halaman), Catatan Rilis (23 halaman), Catatan Rilis (22 halaman), Catatan Rilis (23 halaman), Catatan Rilis (19 halaman), Catatan Rilis (19 halaman), Catatan Rilis (18 halaman), Petunjuk Manual (17 halaman), Catatan Rilis (17 halaman), Petunjuk Peningkatan (16 halaman), Petunjuk Manual (16 halaman), Panduan Petunjuk Instalasi (16 halaman), Catatan Rilis (16 halaman), Catatan Rilis (17 halaman), Catatan Rilis (17 halaman), Catatan Rilis (11 halaman)

HP 316095-B21 - StorageWorks Edge Switch 2/24 Catatan Rilis
Possible switch reset after power failure or power–down sequence
In extremely rare instances, after a power failure or power–down sequence, an Edge
Switch or Director configuration may be reset to factory default settings. This is evident
when HAFM is unable to communicate with the Edge Switch or Director after being
powered on. This occurs because the IP address assigned to the Edge Switch or Director
has been reset to the factory default (10.1.1.10).
Workaround
If this occurs, the Edge Switch or Director configuration and the IP address must be
restored. Also, all licensed features must also be reactivated by reentering the license
keys.
Activating very large zone sets may fail when using OSMS and CT_AUTH
If using third-party applications utilizing Open Systems Management Server with
CT_Authentication enabled, trying to activate a very large zone set may be rejected.
This will be fixed in a future release of firmware.
Workaround
None.
Preferred Domain ID may not update automatically when configuring
SANtegrity features
When configuring SANtegrity, the Preferred Domain ID may not update automatically if
Enterprise Fabric mode or Fabric Binding are enabled and the switch is online.
Workaround
Enable Insistent Domain ID before enabling Enterprise Fabric mode, or make the
Preferred Domain ID the same as the active Domain ID.
Open Source software included in firmware (EOS) 8.x
The following Open Source software is included in firmware 8.x and later:
A) Secure Shell (SSH) 3.6.1p1—OpenSSH component provides a secure
alternative to the telnet server for Command Line Access (CLI) interface.
• BSD-like license is located at the following web site: http://www.openssh.org.
• Secure Shell (SSH) is fully embedded into EOS 8.x.
B) Secure Socket Layer (OpenSSL)—OpenSSL is used for secure connections
between switches.
• BSD-like license is located at the following web site: http://www.openssl.org.
Director and Edge Switch release notes