Juga untuk HP 316095-B21 - StorageWorks Edge Switch 2/24: Manual Pembaruan (9 halaman), Manual (41 halaman), Manual (40 halaman), Catatan Rilis (32 halaman), Catatan Rilis (27 halaman), Manual (26 halaman), Catatan Rilis (27 halaman), Catatan Rilis (25 halaman), Panduan Petunjuk Instalasi (24 halaman), Catatan Rilis (23 halaman), Catatan Rilis (23 halaman), Catatan Rilis (22 halaman), Catatan Rilis (19 halaman), Catatan Rilis (19 halaman), Catatan Rilis (18 halaman), Petunjuk Manual (17 halaman), Catatan Rilis (17 halaman), Petunjuk Peningkatan (16 halaman), Petunjuk Manual (16 halaman), Panduan Petunjuk Instalasi (16 halaman), Catatan Rilis (16 halaman), Catatan Rilis (17 halaman), Catatan Rilis (17 halaman), Catatan Rilis (11 halaman)

HP 316095-B21 - StorageWorks Edge Switch 2/24 Catatan Rilis
Determining current firmware version
This section describes how to determine the current version of firmware for an Edge Switch or Director
using the HAFM, HAFM Basic, or the CLI.
Using HAFM
To determine the current firmware version using HAFM:
1.
Open the Element Manager for the Edge Switch or Director.
2.
Select Product > Properties from the menu bar.
The dialog box displays the firmware version.
Using HAFM Basic
To determine the current firmware version using HAFM Basic (firmware 08.xx.xx or later):
1.
Using the IP address of the switch, log in to the Edge Switch or Director through a web browser.
The Fabric View appears.
2.
Click Details for the Edge Switch or Director.
The Product > Hardware view appears, displaying the firmware version.
Using Embedded Web Server
To determine the current firmware version using Embedded Web Server (firmware 07.xx.xx or earlier):
1.
Using the IP address of the switch, log in to the Edge Switch or Director through a web browser.
2.
Select View from the navigation panel on the left.
3.
Click the Unit Properties tab.
The tab displays the firmware version.

Using the CLI

To determine the current firmware version using the CLI:
1.
Using the IP address of the switch, Telnet to the Edge Switch or Director.
2.
Enter the show system command.
The firmware version appears in the system information display.
Supersedes history
This version supersedes firmware 09.08.01.

Effective date

June 2009
Director and Edge Switch release notes (09.08.03)
21