System Configuration
SYSTEM CAPACITY (GRAINS)
RESIN VOLUME
@ 15 lbs/cu ft @ 10 lbs/cu ft
0.75
22,500
1.00
30,000
1.50
45,000
2.00
60,000
3.00
90,000
Figure 9. Valve Cycle Settings
Injector and Drain Line Flow Control
Automatic Bypass
The regeneration cycle lasts approximately 75 minutes, after which soft water service will be restored.
During regeneration, hard water is automatically bypassed for use in the household. Hot water should be
used as little as possible during this time to prevent hard water from filling the water heater. This is why
automatic regeneration is set for sometime during the night and manual regenerations should be
performed when little or no water will be used in the household.
Safety Float
The brine tank is equipped with a safety float which prevents your brine tank from overfilling as a result of
a malfunction such as a power failure.
New Sounds
You may notice new sounds as your water softener operates. The regeneration cycle lasts approximately
2-1/2 hours. During this time, you may hear water running intermittently to the drain.
Manual Bypass
In the case of emergency, such as an overflowing brine tank, you can isolate your water softener from the
water supply using the bypass valve located at the back of the control. In normal operation the bypass is
open with the on/off knobs in line with the inlet and outlet pipes. To isolate the softener, simply rotate
the knobs counter clockwise until they lock. You can use your water related fixtures and appliances as the
water supply is bypassing the softener. However, the water you use will be hard. To resume soft water
service, open bypass valve by rotating the knobs clockwise.
@ 6 lbs/cu ft
@ 3 lbs/cu ft
(
Factory Setting)
19,875
16,500
10,500
26,500
22,000
14,000
39,750
33,000
21,000
53,000
44,000
28,000
79,500
66,000
42,000
Tank Size (Diameter)
6"
7"
8"
9"
10"
12"
13"
14"
16"
Figure 10. Valve Configurations
Figure 11. Bypass Installation View
CYCLE TIME (MINUTES)
BACKWASH BRINE/RINSE
RINSE
10.0
60.0
10.0
10.0
60.0
10.0
10.0
60.0
10.0
10.0
60.0
10.0
10.0
60.0
10.0
Suggested Softener Valve Configuration
Brine Line Flow
Drain Line Flow
Injector Set
Control (BLFC)
Control (DLFC)
#000 Brown
#1 White
(0.70 GPM)
#2 Blue
#3 Yellow
REFILL TIME (MINUTES) @ 0.70 GPM BLFC
@ 15 lbs/cu ft @ 10 lbs/cu ft
6.0
4.0
7.0
5.0
11.0
7.0
14.0
10.0
21.0
14.0
#1 (1.5 GPM)
#2 (2.0 GPM)
#3 (2.4 GPM)
#4 (3.5 GPM)
#6 (4.0 GPM)
#7 (5.0 GPM)
none
@ 6 lbs/cu ft
@ 3 lbs/cu ft
(
Factory Setting)
2.0
1.1
3.0
1.5
5.0
2.0
6.0
3.0
9.0
4.3
9