AQUATECH 565 Series Panduan Pengoperasian - Halaman 12
Jelajahi secara online atau unduh pdf Panduan Pengoperasian untuk Sistem Penyaringan Air AQUATECH 565 Series. AQUATECH 565 Series 16 halaman. Hto water refiner series
Figure 15. Injector Assembly View
Shut off the water supply to your softener and reduce the pressure by opening a cold soft water
faucet. Using a screwdriver, remove the two screws holding the injector cover to the control valve
body. Carefully remove the assembly and disassemble as shown in Figure 6. The injector orifice is
removed from the valve body by carefully turning it out with a large screwdriver. Remove the
injector throat the same way. Carefully flush all parts including the screen. Use a mild acid such as
vinegar or Pro-Rust Out to clean the small holes in the orifice and throat.
Reassemble using the reverse procedure.
Resin Cleaner
An approved resin cleaner must be used on a regular basis if your water supply contains iron. The
amount of resin cleaner and frequency of use is determined by the quantity of iron in your water
(consult your local representative or follow the directions on the resin package).