HP ProCurve 2124 Ikhtisar Produk - Halaman 3
Jelajahi secara online atau unduh pdf Ikhtisar Produk untuk Beralih HP ProCurve 2124. HP ProCurve 2124 4 halaman. 24-port switch with 10/100 auto-sensing per port and 1 open transceiver slot for a 100base-fx uplink
Juga untuk HP ProCurve 2124: Panduan Tambahan (2 halaman), Brosur & Spesifikasi (5 halaman)
HP ProCurve Switch 2124
Specifications
Ports
Physical characteristics
Dimensions
Weight
Memory and processor
Mounting
Performance
Latency
Switching capacity
MAC address table size
Environment
Operating temperature
Operating relative humidity
Non-operating/Storage temperature
Non-operating/Storage relative humidity
Shock and vibration
Acoustic
Electrical characteristics
Maximum heat dissipation
Voltage
Current
Power consumption
Frequency
Notes
Safety
Emissions
Immunity
Generic
EN
ESD
Radiated
EFT/Burst
Surge
Conducted
Power frequency magnetic field
Voltage dips and interruptions
Harmonics
Flicker
Services
Standards and protocols
HP ProCurve Switch 2124 (J4868A)
24 auto-sensing 10/100 ports (IEEE 802.3 Type 10Base-T, IEEE 802.3u Type 100Base-TX); Media Type: Auto-MDIX; Duplex: half or full
1 open transceiver slot
8.0(d) x 17.4(w) x 1.8(h) in. (20.32 x 44.2 x 4.57 cm) (1U height)
8.25 lb. (3.74 kg), Fully loaded
768 KB
Mounts in a standard 19 in. rack (hardware included)
< 8.5 µs (LIFO)
2.6 Gbps
4,096 entries
32ºF to 131ºF (0ºC to 55ºC)
15% to 95% @ 104ºF (40ºC), non-condensing
-40ºF to 158ºF (-40ºC to 70ºC)
90% @ 149ºF (65ºC), non-condensing
HP759, HP760 (similar to EN 60068 IEC 68)
Power: 42 dB; DIN 27779 per ISO 7779
341 BTU/hr (360 kJ/hr)
100-240 VAC
1.0 A
100 W
50 / 60 Hz
Maximum power rating and maximum heat dissipation are the worst-case theoretical maximum numbers provided for planning the infrastructure with fully loaded
PoE (if equipped), 100% traffic, all ports plugged in, and all modules populated.
cUL (CSA 950); EN 60950/IEC 60950; NOM-019-SCFI-1994; UL 1950 3rd edition
FCC Class A; VCCI Class A; EN 55022/CISPR 22 Class A
EN 55024, CISPR 24
EN 55024, CISPR 24
IEC 61000-4-2; 4 kV CD, 8 kV AD
IEC 61000-4-3; 3 V/m
IEC 61000-4-4; 1.0 kV (power line), 0.5 kV (signal line)
IEC 61000-4-5; 1 kV/2 kV AC
IEC 61000-4-6; 3 V
IEC 61000-4-8; 1 A/m, 50 or 60 Hz
IEC 61000-4-11; >95% reduction, 0.5 period; 30% reduction, 25 periods
EN 61000-3-2, IEC 61000-3-2
EN 61000-3-3, IEC 61000-3-3
3-year, 4-hour onsite, 13x5 coverage for hardware (H5484E)
3-year, 4-hour onsite, 24x7 coverage for hardware (U6300E)
3-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone support (U6299E)
Installation with minimum configuration, system-based pricing (U4826E)
Installation with HP-provided configuration, system-based pricing (U4830E)
Refer to the HP Web site at
www.procurve.com/services
times in your area, please contact your local HP sales office.
General protocols
IEEE 802.3x Flow Control
for details on the service-level descriptions and product numbers. For details about services and response
3