Juga untuk HP StorageWorks 2/16 - SAN Switch: Manual Pembaruan (9 halaman), Panduan Petunjuk Instalasi (20 halaman), Panduan Pengguna (22 halaman), Catatan Rilis Firmware (14 halaman), Catatan Rilis (16 halaman), Panduan Instalasi (14 halaman), Catatan Rilis (10 halaman), Panduan Referensi Cepat (5 halaman)

HP StorageWorks 2/16 - SAN Switch Catatan Rilis
Table 4: Version 3.1.2 Error Messages Not Previously Available (Continued)
Severity & Message
Critical
DIAG-ERRSTAT (BADEOF), 1
Critical
DIAG-ERRSTAT (BADORD), 1
Critical
DIAG-ERRSTAT (CRC), 1
SAN Switch 2/16 Fabric OS 3.1.2 Release Notes
Probable Cause
Port Error Statistics counter is
nonzero, meaning that a Bad end
of file error was detected when
receiving frames. This can be
caused by a faulty cable or
deteriorated SFP. It can also indicate
deeper problems in the
motherboard or ASIC. This message
is generated by the
portloopbacktest or
spinsilk commands, if problems
are found.
Port Error Statistics counter is
nonzero, meaning that a Bad
symbol on fiber-optic
cable error was detected when
receiving frames. This can be
caused by a faulty cable or
deteriorated SFP. It can also indicate
deeper problems in the
motherboard or ASIC. This message
is generated by the
portloopbacktest or
spinsilk commands, if problems
are found.
Port Error Statistics counter is
nonzero, meaning a that a Cyclic
redundancy check on frame
failed error was detected when
receiving frames. This can be
caused by a faulty cable or
deteriorated SFP. It can also indicate
deeper problems in the
motherboard or ASIC. This message
is generated by the
portloopbacktest or
spinsilk commands, if problems
are found.
Documentation Updates
Recommended Action
Check for a faulty cable or
deteriorated SFP. Replace the
cable or SFP if necessary.
If the problem persists:
For the SAN Switch 2/16,
replace the motherboard FRU.
For the SAN Switch 2/8 EL, you
must replace the entire switch.
Check for a faulty cable or
deteriorated SFP. Replace the
cable or SFP if necessary.
If the problem persists:
For the SAN Switch 2/16,
replace the motherboard FRU.
For the SAN Switch 2/8 EL, you
must replace the entire switch.
Check for a faulty cable or
deteriorated SFP. Replace the
cable or SFP if necessary.
If the problem persists:
For the SAN Switch 2/16,
replace the motherboard FRU.
For the SAN Switch 2/8 EL, you
must replace the entire switch.
25