Juga untuk HP StorageWorks 2/16 - SAN Switch: Manual Pembaruan (9 halaman), Panduan Petunjuk Instalasi (20 halaman), Panduan Pengguna (22 halaman), Catatan Rilis Firmware (14 halaman), Catatan Rilis (32 halaman), Panduan Instalasi (14 halaman), Catatan Rilis (10 halaman), Panduan Referensi Cepat (5 halaman)

HP StorageWorks 2/16 - SAN Switch Catatan Rilis
The switch will send one copy of a trap message to each IP address that is listed in
the communities. If you enter the same IP address into more than one of the
communities, you will get multiple copies of the same trap message.
Note:
SAN Switch 2/16 Version 3.0.2k Release Notes
swEventTrapLevel: (0..5)—must be set for a severity level from 0 to 5
— 0 – none
— 1 – critical
— 2 – error
— 3 – warning
— 4 – informational
— 5 – debug
authTrapsEnabled: (true, t, false, f)—must be set to true or t to enable
sending of traps
This parameter is set to
true
t
or
by default.
SNMP-based Management