HP StorageWorks 8/24 - SAN Switch Catatan Rilis
Closed defect summary
An "ipfilter --transabort" command running in one Telnet
session can be aborted from another Telnet session.
Cannot set "Portlog events enable" accurately.
The DC Director may ASSERT in a specific test scenario while running
a particular FICON test program (SAK IRNDUP).
Brocade 4-Gb SAN Switch for HP c-Class BladeSystem power-on-self-
test (POST) failure on chassis power on.
Flooding of an unknown inter-switch FDMI command from another
vendor's switch is causing the switch to crash.
DC Director port blades are re-initialized during supportsave.
2-Gb Channels fail to come online from T-Rexx mainframe to a 128-
port 4/256 SAN Director.
Occasional kernel panic during reboot in AG setup.
Under very rare conditions, and in a configuration where there are
multiple paths configured to reach multiple devices, some paths were
observed not coming online.
During fastwrite, a 3rd party device drops a status frame due to
data alignment.
HaFailover not working after upgrading firmware from Fabric OS
5.0 to 5.2.0a using firmrwaredownload -s on each CP.
Heart beat missing being reported by CP - Standby CP reboots.
FICON Virtual Tape Pipelining does not function correctly with specific
tape devices.
Blade fault does not result in LIRR and async status.
Firmware upgrade on 4/8 SAN Switch and 4/16 SAN Switch to
Fabric OS 6.0.0 will cause the switch to report marginal state.
CUP Set Offline inline command not presenting status before going
offline.
Usability: Ctrl-C in legacy configdownload code is not blocked
during downloads.
Switch faults if Management Server Domain is invalid, limited com-
mands available.
When a switch's IDID mode is currently OFF and we disable the switch,
the rest of the switches in the fabric get a premature duplicate message.
Async error reporting events are lost if detected immediately after
switch boot.
Fabric Manager: Configdownload actually downloads all the dis-
ruptive parameters in the Validation step in Fabric Manager, when
the switch is in a disabled state.
Solution
Fixed in Fabric OS 6.1.0
Fixed in Fabric OS 6.1.0
Fixed in Fabric OS 6.1.0
Fixed in Fabric OS 6.1.0
Fixed in Fabric OS 6.1.0
Fixed in Fabric OS 6.1.0
Fixed in Fabric OS 6.1.0
Fixed in Fabric OS 6.1.0
Fixed in Fabric OS 6.1.0
Fixed in Fabric OS 6.1.0
Fixed in Fabric OS 6.1.0
Fixed in Fabric OS 6.1.0
Fixed in Fabric OS 6.1.0
Fixed in Fabric OS 6.1.0
Fixed in Fabric OS 6.1.0
Fixed in Fabric OS 6.1.0
Fixed in Fabric OS 6.1.0
Fixed in Fabric OS 6.1.0
Fixed in Fabric OS 6.1.0
Fixed in Fabric OS 6.1.0
Fixed in Fabric OS 6.1.0
HP StorageWorks Fabric OS 6.1.0h release notes
19