Fibre Channel ports
Fibre Channel ports
Fibre Channel ports
Fibre Channel ports
Device support and
Device support and
Device support and
Device support and
Scalability guidelines
Scalability guidelines
Scalability guidelines
Scalability guidelines
Performance
Performance
Performance
Performance
Certified maximum
Certified maximum
Certified maximum
Certified maximum
Switch core
Switch core
Switch core
Switch core
Fabric latency
Fabric latency
Fabric latency
Fabric latency
Maximum frame size
Maximum frame size
Maximum frame size
Maximum frame size
Classes of service
Classes of service
Classes of service
Classes of service
Port types
Port types
Port types
Port types
Data traffic types
Data traffic types
Data traffic types
Data traffic types
Media types
Media types
Media types
Media types
Laser
Laser
Laser
Laser
Fabric services
Fabric services
Fabric services
Fabric services
Options
Options
Options
Options
Supported software
Supported software
Supported software
Supported software
Management access
Management access
Management access
Management access
Diagnostics
Diagnostics
Diagnostics
Diagnostics
Dimensions
Dimensions
Dimensions
Dimensions
Environment
Environment
Environment
Environment
Brocade 4/12 SAN Switch model:
12 4Gb ports in any internal/external port combination (ships with two 4Gb short wave SFPs)
Brocade 4/24 SAN Switch models:
16 internal 4Gb ports and 8 external 4Gb auto-sensing ports (ships with four 4Gb short wave SFPs)
http://h18006.www1.hp.com/products/storageworks/san/documentation.html
4 Gb/sec line speed, full duplex
Certified maximum information available at:
http://h18006.www1.hp.com/products/storageworks/san/documentation.html
Non-blocking
1.2 µ sec. with no contention, cut-through routing at 4Gb. Latency increases as input port speed
increases and becomes disparate from output port speed.
2112-byte payload
Class 2, Class 3, Class F (inter-switch frames)
FL_Port, F_Port, and E_Port; self-discovery based on switch type (U_Port)
Fabric switches supporting unicast and broadcast
Small Form-Factor Pluggable (SFP) Transceiver. 1/2/4Gb short wave up to 500 m (1,640 ft.) and
1/2/4Gb long wave* up to 10 km
Short-wave and long-wave laser transceivers (SFP's) are supported
Simple Name Server, Registered State Change Notification (RSCN). Includes Advanced WebTools and
Advanced Zoning. Optional fabric services include: Fabric Watch, ISL Trunking, Advanced Performance
Monitoring, and Extended Fabrics.
SFP media, port upgradeable licensing, advanced management software licensing
Telnet, SNMP (FE MIB, FC Management MIB), HP Systems Insight Manager, HP Storage Essentials, HP
Onboard Administrator for BladeSystem, Advanced WebTools, Advanced Zoning, Fabric Manager,
Fabric Watch, and Advanced Performance Monitoring
WebTools, SMI-s provider, SNMP, Telnet, and Secure Telnet
POST and embedded online/offline diagnostics
Depth
Height
Width
Weight
System Inlet Temperature
System Inlet Temperature
System Inlet Temperature Operating
System Inlet Temperature
Relative Humidity
Relative Humidity
Relative Humidity
Relative Humidity
DA - 12480
Worldwide — Version 9 — July 13, 2007
Brocade 4Gb SAN Switch for HP c-Class BladeSystem
Brocade 4Gb SAN Switch for HP c-Class BladeSystem
Brocade 4Gb SAN Switch for HP c-Class BladeSystem
Brocade 4Gb SAN Switch for HP c-Class BladeSystem
11.00 in. (with handle protrusion)
1.13 in.
7.63 in.
Approx. 2.85 lb - without media
Non-operating
Operating
Non-operating
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305m (1.8°F
per every 1000ft) above sea level to a maximum
of 3050m (10,000ft), no direct sustained
sunlight. Maximum rate of change is 10°C/Hr
(18°F/Hr ). The upper limit may be limited by the
type and number of options installed.
System performance may be reduced if operating
with a fan fault or above 30°C (86°F).
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/Hr (36°F/Hr).
10 to 90% relative humidity (Rh), 28°C (82.4°F)
maximum wet bulb temperature, non-
condensing.
5 to 95% relative humidity (Rh), 38.7°C (101.7°F)
maximum wet bulb temperature, non-
condensing.
Page 13