HP StorageWorks XP10000 - Disk Array Panduan Konfigurasi - Halaman 15

Jelajahi secara online atau unduh pdf Panduan Konfigurasi untuk Beralih HP StorageWorks XP10000 - Disk Array. HP StorageWorks XP10000 - Disk Array 40 halaman. Cache lun xp
Juga untuk HP StorageWorks XP10000 - Disk Array: Catatan Rilis (13 halaman), Panduan Administrator (50 halaman), Panduan Konfigurasi (42 halaman), Panduan Konfigurasi (40 halaman), Panduan Konfigurasi (36 halaman), Panduan Konfigurasi (36 halaman), Panduan Konfigurasi (30 halaman), Panduan Konfigurasi (36 halaman), Catatan Rilis (5 halaman), Panduan Konfigurasi Sistem (49 halaman), Panduan Konfigurasi Sistem (43 halaman), Panduan Konfigurasi Sistem (42 halaman), Panduan Konfigurasi Sistem (35 halaman), Panduan Konfigurasi (46 halaman), Panduan Konfigurasi (46 halaman), Panduan Konfigurasi (40 halaman), Panduan Konfigurasi (44 halaman), Panduan Konfigurasi (38 halaman), Panduan Konfigurasi (34 halaman), Panduan Konfigurasi (30 halaman), Panduan Konfigurasi (30 halaman), Panduan Konfigurasi (42 halaman), Panduan Pengguna (30 halaman)

HP StorageWorks XP10000 - Disk Array Panduan Konfigurasi

Connecting the disk array

The HP service representative connects the disk array to the host by:
1.
Verifying operational status of the disk array channel adapters, LDEVs, and paths.
2.
Connecting the Fibre Channel cables between the disk array and the fabric switch or host.
3.
Verifying the ready status of the disk array and peripherals.

Restarting the Linux server

To recognize the new device(s), restart the Linux server as follows:
1.
Power on the display of the Linux server.
2.
Power on all devices other than the Linux server.
3.
Confirm ready status of all devices.
4.
Power on the Linux server.

Verifying new device recognition

1.
Verify that the FCA driver is installed using the lsmod command.
2.
View the device information in the /proc/scsi/scsi file.
Example
#cat /proc/scsi/scsiAttached devices:
Host: scsi0 Channel: 00 Id: 00 Lun: 00
Vendor: HP
Type:
Host: scsi0 Channel: 00 Id: 00 Lun: 01
Vendor: HP
Type:
Host: scsi0 Channel: 00 Id: 00 Lun: 02
Vendor: HP
Type:
Host: scsi0 Channel: 00 Id: 00 Lun: 03
Vendor: HP
Type:
Model: OPEN-9
Direct-Access
Model: OPEN-9
Direct-Access
Model: OPEN-9
Direct-Access
Model: OPEN-9
Direct-Access
Rev: 2105
ANSI SCSI revision: 02
Rev: 2105
ANSI SCSI revision: 02
Rev: 2105
ANSI SCSI revision: 02
Rev: 2105
ANSI SCSI revision: 02
XP Disk Array Configuration Guide for Linux
15