HP XP20000/XP24000 Panduan Konfigurasi - Halaman 11

Jelajahi secara online atau unduh pdf Panduan Konfigurasi untuk Beralih HP XP20000/XP24000. HP XP20000/XP24000 30 halaman. Hp storageworks xp disk array configuration guide: vmware (a5951-96106, september 2010)
Juga untuk HP XP20000/XP24000: Catatan Rilis (13 halaman), Manual Integrasi (29 halaman), Catatan Rilis (4 halaman), Panduan Administrator (50 halaman), Panduan Konfigurasi (42 halaman), Panduan Konfigurasi (40 halaman), Panduan Konfigurasi (40 halaman), Panduan Konfigurasi (36 halaman), Panduan Konfigurasi (36 halaman), Panduan Konfigurasi (36 halaman), Catatan Rilis (5 halaman), Panduan Konfigurasi (46 halaman), Panduan Konfigurasi (46 halaman), Panduan Referensi (46 halaman), Panduan Konfigurasi (40 halaman), Panduan Konfigurasi (44 halaman), Panduan Konfigurasi (38 halaman), Panduan Konfigurasi (34 halaman), Panduan Konfigurasi (30 halaman), Panduan Konfigurasi (30 halaman)

HP XP20000/XP24000 Panduan Konfigurasi

Setting system option modes

The HP service representative sets system option modes based on the operating system and software
configuration of the host. In some situations, the system option modes shown in
enable storage system behaviors that are more compatible with the requirements of a NonStop system
than the default modes. Ask your service representative if these modes apply in your situation.
Table 1 System option modes
System
nl
Option Mode
142
325
352
454
1
685
1
System option mode 685 enhances the performance of the XP storage systems during the repair or
replacement of a cache board. When this mode is used, XP storage systems display consistent I/O
processing response times throughout the repair action. To use system option mode 685, four or more
cache PC boards must be installed. Do not set system option mode 685 in XP storage systems containing
only two cache PC boards.
HP also recommends setting host group mode 13 with XP storage systems that are connected to HP
NonStop systems.
Contact your HP storage service representative for information about these configuration options.
Notify your HP service representative if you install backup or other software that requires specific
settings on the storage system.

Configuring the Fibre Channel ports

Configure the disk array Fibre Channel ports by using XP Remote Web Console (shown) or XP
Command View Advanced Edition Software. Select the settings for each port based on your storage
area network topology. Use switch zoning if you connect different types of hosts to the array through
the same switch.
XP128/XP1024
21-09-02-00/00 or later
21-14-02-00/00 or later
21-14-35-00/00 or later
N/A
N/A
Minimum microcode version
XP10000/XP12000
Available from initial release
N/A
50-09-34-00/00 or later
50-03-93-00/00 or later
N/A
XP Disk Array Configuration Guide for NonStop
Table 1
on page 11
XP20000/XP24000
Available from initial release
N/A
N/A
Available from initial release
60-02-25-00/00 or later
11