HP XP20000/XP24000 Panduan Konfigurasi - Halaman 19

Jelajahi secara online atau unduh pdf Panduan Konfigurasi untuk Beralih HP XP20000/XP24000. HP XP20000/XP24000 46 halaman. Hp storageworks xp disk array configuration guide: vmware (a5951-96106, september 2010)
Juga untuk HP XP20000/XP24000: Catatan Rilis (13 halaman), Manual Integrasi (29 halaman), Catatan Rilis (4 halaman), Panduan Administrator (50 halaman), Panduan Konfigurasi (42 halaman), Panduan Konfigurasi (40 halaman), Panduan Konfigurasi (40 halaman), Panduan Konfigurasi (36 halaman), Panduan Konfigurasi (36 halaman), Panduan Konfigurasi (30 halaman), Panduan Konfigurasi (36 halaman), Catatan Rilis (5 halaman), Panduan Konfigurasi (46 halaman), Panduan Referensi (46 halaman), Panduan Konfigurasi (40 halaman), Panduan Konfigurasi (44 halaman), Panduan Konfigurasi (38 halaman), Panduan Konfigurasi (34 halaman), Panduan Konfigurasi (30 halaman), Panduan Konfigurasi (30 halaman)

HP XP20000/XP24000 Panduan Konfigurasi
Ensure you have the latest supported version of the lpfc driver (available from
www.emulex.com).
Edit the /kernel/drv/lpfc.conf driver configuration file to set up the FCA for a SAN infra-
structure:
topology = 2;
If multiple FCAs and VxVM are used, adjust the following parameters to assure correct VxVM
behavior:
no-device-delay=0;
nodev-tmo=30;
linkdown-tmo=30; # verify, should be default value
Persistent bindings are necessary in a fabric topology and are used to bind a SCSI target ID to a
particular WWPN (of an array port). This is required to guarantee that the SCSI target IDs will
remain the same when the system is rebooted. Persistent bindings can be set by editing the con-
figuration file or by using the lputil utility. The following example illustrates the binding of target
20 (lpfc instance 2) to WWPN 50060e8003285301 and the binding of target 30 (lpfc instance
0) to WWPN 50060e8003285311:
fcp-bind-WWPN="50060e8003285301:lpfc2t20",
"50060e8003285311:lpfc0t30";
(Replace the WWPNs above with the WWPNs for your array ports.)
For each LUN that needs to be accessed, add an entry to the /kernel/drv/sd.conf file. For
example, assume you want to access LUNs 1 and 2 through both paths. You would add the fol-
lowing entries (preferably at the end of the file):
name="sd" parent="lpfc" target=20 lun=1;
name="sd" parent="lpfc" target=20 lun=2;
name="sd" parent="lpfc" target=30 lun=1;
name="sd" parent="lpfc" target=30 lun=2;
Perform a reconfiguration reboot to implement the changes to the configuration files.
If LUNs have been preconfigured in the /kernel/drv/sd.conf file, use the devfsadm command
to perform LUN rediscovery after configuring LUNs as explained in
paths" on page 10.

Configuring Qlogic FCAs with the qla2300 driver

NOTE:
The qla2300 driver cannot be used with Sun StorEdge Traffic Manager/Sun Storage Multipathing.
To configure a Qlogic FCA using the Sun SAN driver stack, refer to
SAN driver
stack" on page 17.
Contact your HP representative to determine which QLogic FCAs and driver version HP supports with
the qla2300 driver. The qla2300 driver is not supported on x86 architecture. Configure Qlogic FCAs
with the qla2300 driver as follows:
"Defining the
"Configuring FCAs with the Sun
XP Disk Array Configuration Guide: Solaris
http://
19