HP XP20000/XP24000 Panduan Konfigurasi - Halaman 7

Jelajahi secara online atau unduh pdf Panduan Konfigurasi untuk Beralih HP XP20000/XP24000. HP XP20000/XP24000 46 halaman. Hp storageworks xp disk array configuration guide: vmware (a5951-96106, september 2010)
Juga untuk HP XP20000/XP24000: Catatan Rilis (13 halaman), Manual Integrasi (29 halaman), Catatan Rilis (4 halaman), Panduan Administrator (50 halaman), Panduan Konfigurasi (42 halaman), Panduan Konfigurasi (40 halaman), Panduan Konfigurasi (40 halaman), Panduan Konfigurasi (36 halaman), Panduan Konfigurasi (36 halaman), Panduan Konfigurasi (30 halaman), Panduan Konfigurasi (36 halaman), Catatan Rilis (5 halaman), Panduan Konfigurasi (46 halaman), Panduan Referensi (46 halaman), Panduan Konfigurasi (40 halaman), Panduan Konfigurasi (44 halaman), Panduan Konfigurasi (38 halaman), Panduan Konfigurasi (34 halaman), Panduan Konfigurasi (30 halaman), Panduan Konfigurasi (30 halaman)

HP XP20000/XP24000 Panduan Konfigurasi
1 Installing and configuring Solaris for the
XP family of disk arrays
You and the HP service representative each play a role in installation. The HP service representative
is responsible for installing the disk array and formatting the disk devices. You are responsible for
configuring the host server for the new devices with assistance from the HP service representative.

Features and requirements

The disk array has the following features:
Storage capacity: The storage capacity for each model is listed below:
Model
XP24000
XP20000
XP12000
XP10000
SVS 200
Server support: Sun servers (SPARC and x86), FSC servers, HP servers (x86). Check with your HP
representative for the servers and Fibre Channel adapters supported by your disk arrays.
Operating system support: For supported disk array microcode and OS versions, see the HP
SPOCK website:
Before installing the disk array, ensure the following requirements are met:
Volume Manager: Solaris Volume Manager or Veritas Volume Manager.
Sun SAN software: For Solaris 8/9 (if not using Emulex, Qlogic, or JNI drivers), latest SAN
Foundation Software with current patches. For Solaris 10 (if not using Emulex, or Qlogic drivers),
latest SAN (Leadville driver stack) with current patches.
Sun StorEdge Traffic Manager/Sun Storage Multipathing requires that you configure /kernel/drv/sc-
si_vhci.conf.
For Solaris 8/9 SAN information, refer to Sun StorEdge SAN Foundation Software & Installation
Guide and Sun StorEdge Traffic Manager Software Installation and Configuration Guide at
/www.sun.com.
For Solaris 10 and later SAN information, refer to Solaris Fibre Channel and Storage Multipathing
Administration Guide at http://docs.sun.com.
Fibre Channel Adapters (FCAs): Install FCAs and all utilities and drivers. Refer to the adapter doc-
umentation for installation details.
Maximum drives
Maximum Capacity
1152
2.26 PB
240
472 TB
1152
454 TB
240
94.5 TB
External
124 TB
http://spock.corp.hp.com
Maximum FC ports
224 4GB or 24 8GB
48 4GB or 24 8GB
224 4GB
48 4GB
48
XP Disk Array Configuration Guide: Solaris
http:/
7