Juga untuk HP XP20000/XP24000: Catatan Rilis (13 halaman), Manual Integrasi (29 halaman), Catatan Rilis (4 halaman), Panduan Administrator (50 halaman), Panduan Konfigurasi (42 halaman), Panduan Konfigurasi (40 halaman), Panduan Konfigurasi (40 halaman), Panduan Konfigurasi (36 halaman), Panduan Konfigurasi (36 halaman), Panduan Konfigurasi (30 halaman), Panduan Konfigurasi (36 halaman), Catatan Rilis (5 halaman), Panduan Konfigurasi (46 halaman), Panduan Konfigurasi (46 halaman), Panduan Referensi (46 halaman), Panduan Konfigurasi (40 halaman), Panduan Konfigurasi (44 halaman), Panduan Konfigurasi (38 halaman), Panduan Konfigurasi (30 halaman), Panduan Konfigurasi (30 halaman)

HP XP20000/XP24000 Panduan Konfigurasi
Heterogeneous operating systems can share an array port if you set the appropriate host group
and mode. All others must connect to a dedicated array port.
Use LUN Manager for LUN isolation when multiple hosts connect through a shared array port.
LUN Manager provides LUN security by allowing you to restrict which LUNs each host can access.
QLogic and Emulex FCAs must be in separate zones (a QLogic zone and an Emulex zone)
whether the FCAs are in the same or separate servers.
If booting over the SAN, within a server, the booting FCAs must be from the same vendor. Addi-
tional data storage FCAs can be from a different vendor.
Table 5 Fabric zoning and LUN security settings
Environment
Standalone SAN
(non-clustered)
Clustered SAN
Multi-Cluster SAN
If you plan to use clustering, install and configure the clustering software on the servers. Clustering
is the organization of multiple servers into groups. Within a cluster, each server is a node. Multiple
clusters compose a multi-cluster environment. The following example shows a multi-cluster environ-
ment with three clusters, each containing two nodes. The nodes share access to the disk array.
Figure 3 Multi-cluster environment
.

Connecting the disk array

The HP service representative performs the following steps to connect the disk array to the host:
1.
Verifying operational status of the disk array channel adapters, LDEVs, and paths.
2.
Connecting the Fibre Channel cables between the disk array and the fabric switch or host.
3.
Verifying the ready status of the disk array and peripherals.
OS mix
homogeneous (a
single OS type
Not required
present in the SAN)
heterogeneous (more
than one OS type
Required
present in the SAN)
XP Disk Array Configuration Guide: Windows
Fabric zoning
LUN security
Must be used when
multiple hosts or
cluster nodes connect
through a shared port
15