aquatherm Calorex AT500 Panduan Pemasangan & Pengoperasian - Halaman 4
Jelajahi secara online atau unduh pdf Panduan Pemasangan & Pengoperasian untuk Pompa Panas aquatherm Calorex AT500. aquatherm Calorex AT500 16 halaman. Swimming pool & spa heat pumps
B. HEAT PUMP PLACEMENT & CLEARANCES
AIR COIL
AIR FLOW IN
S
ON 3 SIDE
1. To allow for proper condensation
drainage, use a level slab to elevate
the heat pump to at least the same
height as the pool filter system slab,
or 2 to 3 inches minimum above
grade.
2. Allow the minimum air flow clear-
ances on top and the sides as shown
here. Do not install indoors or where
the discharge air can accumulate and
be drawn back through the heater.
Make sure the front is accessible
for future service.
3. Keep sprinkler heads at least 6 feet
away from the heat pump. Do not
allow the sprinkler to spray the unit
in any way to prevent damage.
4. If the unit is installed under a roof
overhang or under a roof valley, a
gutter or diverter should be fitted to
prevent excessive water from pour-
ing through the unit.
5. Keep all plants and shrubs trimmed
away from the heater to the mini-
mum clearances shown here to
prevent air coil damage.
FAN DISCHARGE
WATER IN/OUT PORT
INDICATOR LABEL
Minimum Air Flow
& Access
Clearances
AIR
COIL
12"
48"
2"
3.
AIR FLOW OUT
BASE
CONCRETE OR
PREFAB
2" THREADED MALE
PIPING CONNECTIONS
BACK
9"
12"
TOP
12"
FRONT
36"
6 FT