1. PUTTING INTO SERVICE
1.2)
Switching On / Off of the electrical main motor
The blade drive is effected by a 400 Volt three phase electric engine with 15kW power.
To start the engine, use the main switch installed on the engine. When starting the engine
check that neither your hands nor your foots reach the cutting area, note the you can
seriously be injured when getting in contact with the rotating saw blade.
To start turn the main switch 08 up to the position "star" and you stay in this position until the
diamond saw has reached its full revolutions (approx. 10-15 seconds). Then turn the switch
up to the position "triangle" . According to the direction of rotation of the diamond saw (rotating
direction shown by an arrow on the cover hood), you have to turn the main switch in to the
opposite direction.
It's important, that the machine is started in this order since otherwise
the net is overloaded.
If the engine is operated in the permanent operation into switch position
"star", the motor is missing performance and it will take damage. The
Danger
engine works only in the position "triangle" in the permanent operation.
When turning the engine off you turn the main switch slowly backwards in the 2 steps to the
'0-position'. The Emergency-Button 07 on the top of the switch is always at your disposal. The
Emergency-Button 07 is pressed by pushing.
It is pointed out, to particularly, that the rearrangement to another tension or current intensity
only may be carried out by an expert.
The appropriate prescriptions of the VDE/SEV and the electricity works have to be observed at
connection of the engine. The connection network has to be checked. To protect the engine and
persons from damage, whether the being device is grounded net-sided unobjectionable has to
be checked.