DIAVITE AG DIAVITE Compact VH Manual - Halaman 6

Jelajahi secara online atau unduh pdf Manual untuk Alat Ukur DIAVITE AG DIAVITE Compact VH. DIAVITE AG DIAVITE Compact VH 14 halaman.

DIAVITE AG DIAVITE Compact VH Manual
1.4
Connection of the tracer
Attention: No measuring is possible without connected tracer and traverse unit.
Remove the supporting shoe by using the enclosed hexagon key (type VH) or by
means of the knurled nut (type VHF).
Traverse unit VH or VHF
Insert the tracer into the traverse unit as shown in the picture. The two red points must match each
other. If manual measurements are to be effected, remount the supporting shoe to the traverse unit
again.
Warning:
By no means the tracer is to be inserted forcefully; it must be held with the utmost
The position of the supporting shoe is reached correctly when the work piece is supported on its whole
length by the traversing unit with supporting shoe. If the measuring area is too small, the bottom
surfaces of traversing unit and the supporting shoe must be on the same level.
Warning:
When measuring together with the support, please make sure that the tracer is not
bent by lowering it too deeply onto the work piece. There is no guarantee for bent tracers.
1.5

Traverse unit

The number of the instrument and the number of the traverse unit must be identically!
Prior to starting the instrument, connect the traverse unit to the measuring unit with the 6-core
connection cable. This cable provides the traverse unit with the necessary electric tension and
transmits the measuring signal.
The cable plugs for the connection cable have an integrated locking. The cable must, therefore, be
held at the plugs only when being inserted or removed, as otherwise the connection between cable
and plug could become damaged.
1.6

Switch-on/off of the instrument

The instrument can be switched-on with any of the keys. It can be operated with the incorporated
rechargeable batteries or by means of the electric mains adapter directly from the mains (see 2.6
electric power supply).
If for some time no key of the instrument had been pressed, the instrument would switch-off
automatically. The duration of time for automatic switch-off can be set (see 3.1 Menu – Config –
Switch-off). A manual switch-off is not possible.
DIAVITE COMPACT
care at its largest diameter!
5
Supporting shoe