Installation
5 Installation
5.1
DIN rail installation
1
5.2
On-surface installation (only 230 V versions)
1
6 Connections
Warning
Danger to life due to the electrical voltage at the base station!
• Only an authorised electrician may open the device.
• Always disconnect from the mains network and secure against unintended activation before opening.
• Disconnect external voltages and secure against activation.
The wiring of a room-by-room temperature control system depends on several factors and must be
planned and carried through carefully by the installer. The following cross-sections are applicable for
the plug-in/clamping connections:
• solid wire: 0.5 – 1.5 mm²
• flexible wire: 1.0 – 1.5 mm²
• 8 - 9 mm insulation stripped off the wire
The wires of the actuators can be used with factory-mounted end sleeves.