Load mode
● Manual Control:Control the load via the button.
●Light ON/OFF
Note: In the mode of Light ON/OFF and Light ON/Timer, the Load is turned on after
10Min. delay.
● Test Mode (Default):Test Mode is as same as Light Control Mode but no delay.
The correspondence table of Load Work Mode & LED digital tube value
Value
Working mode
Light ON/OFF
Light ON + 1 hours
Light ON + 2hours
Light ON + 3hours
Light ON + 4 hours
Light ON + 5 hours
Light ON + 6 hours
Light ON + 7 hours
4. Troubleshooting
Faults
Possible reasons
Charging LED indicator
off during daytime
PV array
when sunshine falls on
disconnection
PV modules properly
Battery voltage
higher than over
Charging Status LED
voltage
indicator fast flashing
disconnect
voltage
Battery LED indicators
Battery over
red color and loads not
discharged
working
●Light ON + Timer
Value
Working mode
Light ON + 8 hours
Light ON + 9 hours
Light ON + 10 hours
Light ON + 11 hours
Light ON + 12 hours
Light ON + 13 hours
Manual Control
Test Mode
Troubleshooting
Check that PV and battery wire
connections are correct and tight
1. Disconnect the solar array and
measure the battery voltage whether is
too high; 2. Change the controller; 3.
Change the battery
The controller cut off the output
automatically. LED indicator will return to
green automatically when fully
3
The radix point of
digital tube fast
Short circuit
flashing and load not
working
The radix point of
digital tube slowly
Over load
flashing and load not
working
6. Technical Specifications
Item
LS1012EPD
Nominal system voltage
12VDC
Max. PV input voltage
30V
Rated current
10A
Equalize Voltage
Boost Voltage
Float Voltage
Low Voltage Reconnect
Voltage
Low Voltage Disconnect
Voltage
Self-consumption
Temperature
compensation coefficient
Working temperature
Enclosure
Overall dimension
Mounting dimension
Mounting hole size
Power cable
Net weight
Any changes without prior notice!
Clear short circuit. It is reactivated after
delayed 10 seconds for the first time, If
over 1 time,press the key to clear error
and the controller will resume to work
after 3s or restart the controller
Please reduce the number of electric
equipments.
When load power reaches 1.25-1.5
times, 1.5-2 times and 2 times more than
nominal value, controller will
automatically close loads in 60 seconds,
5 seconds and 1 second, respectively.
Please press the key to clear error and
the controller will resume to work after 3s
or restart the controller
LS1024EPD
LS2024EPD
12/24VDC Auto
12/24VDC Auto
50V
10A
14.8V(12V);29.6V(24V)
14.4V(12V);28.8V(24V)
13.7V(12V);27.4V(24V)
12.6V(12V);25.2V(24V)
11.2V(12V);22.4V(24V)
12V:≤4.58mA;24V:≤6.01mA
-5mV/℃/2V(25℃)
-35℃~+55℃
IP67
108.5mm×75mm×25.6mm
100.5mm
Φ5
2
PV/BAT/LOAD:4.0mm
PV/BAT/LOAD:6.0mm
408g
410g
Version number:V1.1
4
50V
20A
2
435g